Chromatographic purity
Mobile phaseand Chromatographic system
Prepare as directed in the Assay.
Test solution
Transfer about 10mg of Atenolol to a 100-mLvolumetric flask,dissolve in and dilute with Mobile phaseto volume,and mix.
Diluted test solution
Transfer 0.50mLof the Test solutionto a 100-mLvolumetric flask,dilute with Mobile phaseto volume,and mix.
Procedure
Separately inject equal volumes (about 50µL)of the
Test solutionand the
Diluted test solutioninto the chromatograph,record the chromatograms,and measure the areas for all the peaks.
[NOTEChromatograph the
Test solution for a period of time 6times the retention time of the atenolol peak.
]Calculate the percentage of each impurity observed in the chromatogram obtained from the
Test solutionby the formula:
0.5(ri/rA),
in which
riis the peak response of an individual impurity in the chromatogram obtained from the
Test solution;and
rAis the response of the main atenolol peak in the chromatogram obtained from the
Diluted test solution.Not more than 0.25%of any individual impurity is found,and the sum of all the impurities is not more than 0.5%.
Assay
Mobile phase
Dissolve 1.1g of sodium 1-heptanesulfonate and 0.71g of anhydrous dibasic sodium phosphate in 700mLof water.Add 2mLof dibutylamine,and adjust with 0.8
Mphosphoric acid to a pHof 3.0.Add 300mLof methanol,mix,and pass through a filter having a 0.5µm or finer porosity.Degas this solution before use.Make adjustments if necessary (see
System Suitabilityunder
Chromatography á621ñ).
Standard preparation
Quantitatively dissolve an accurately weighed quantity of
USP Atenolol RSin
Mobile phaseto obtain a solution having a known concentration of about 0.01mg per mL.
Assay preparation
Transfer about 100mg of Atenolol,accurately weighed,to a 100-mLvolumetric flask,add 50mLof Mobile phase,and sonicate for about 5minutes.Dilute with Mobile phaseto volume,and mix.Transfer 5.0mLof this solution to a 50-mLvolumetric flask,dilute with Mobile phaseto volume,and mix.Transfer 5.0mLof this solution to a second 50-mLvolumetric flask,dilute with Mobile phaseto volume,and mix.
Chromatographic system(see Chromatography á621ñ)
The liquid chromatograph is equipped with a 226-nm detector and a 3.9-mm ×30-cm column that contains packing L1.The flow rate is about 0.6mLper minute.Chromatograph the
Standard preparation,and record the peak responses as directed for
Procedure:the column efficiency is not less than 5000theoretical plates;the tailing factor is not more than 2.0;and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 10µL)of the
Standard preparationand the
Assay preparationinto the chromatograph,record the chromatograms,and measure the responses for the major peaks.Calculate the quantity,in mg,of C
14H
22N
2O
3in the portion of Atenolol taken by the formula:
100C(rU/rS),
in which
Cis the concentration,in mg per mL,of
USP Atenolol RSin the
Standard preparation;and
rUand
rSare the atenolol peak responses obtained from the
Assay preparationand the
Standard preparation,respectively.