Packaging and storage
Preserve in suitable,tight containers.
Labeling
Label it to indicate the method of preparation and that it is not for parenteral administration.
pHá791ñ:
between 5.0and 7.0in a solution containing 0.3mLof saturated potassium chloride solution per 100mLof test specimen.
Ammonia
For containers having a fill volume of less than 50mL,dilute 50mLof it with 50mLof
High-Purity Water(see
Reagentsunder
Containers á661ñ),and use this dilution as the test solution;where the fill volume is 50mLor more,use 100mLof it as the test solution.To 100mLof the test solution add 2mLof alkaline mercuric-potassium iodide TS:any yellow color produced immediately is not darker than that of a control containing 30µg of added ammonia (furnished by adding 1.76mLof 1.0Nammonium hydroxide)in 100mLof
High-Purity Water.This corresponds to a limit of 0.6mg per Lfor containers having a fill volume of less than 50mLand 0.3mg per Lwhere the fill volume is 50mLor more.
Calcium
To 100mLadd 2mLof ammonium oxalate TS:no turbidity is produced.
Carbon dioxide
To 25mLadd 25mLof calcium hydroxide TS:the mixture remains clear.
Chloride
To 20mLin a color-comparison tube add 5drops of nitric acid and 1mLof silver nitrate TS,and gently mix:any turbidity formed within 10minutes is not greater than that produced in a similarly treated control consisting of 20mLof
High-Purity Water(see
Reagentsunder
Containers á661ñ),containing 10µg of Cl (0.5mg per L),viewed downward over a dark surface with light entering the tubes from the sides.
Sulfate
To 100mLadd l mLof barium chloride TS:no turbidity is produced.
Oxidizable substances
To 100mL,add 10mLof 2Nsulfuric acid,and heat to boiling.For Sterile Purified Water in containers having a fill volume of less than 50mL,add 0.4mLof 0.1Npotassium permanganate,and boil for 5minutes;where the fill volume is 50mLor more,add 0.2mLof 0.1Npotassium permanganate,and boil for 5minutes.If a precipitate forms,cool in an ice bath to room temperature,and pass through a sintered-glass filter:the pink color does not completely disappear.
Auxiliary Information
Staff Liaison:
Francis P.Barletta
Expert Committee:(PW)Pharmaceutical Waters
USP28NF23Page 2035
Pharmacopeial Forum:Volume No.30(4)Page 1317
Phone Number:1-301-816-8328