Glycine,N,N¢-1,2-ethanediylbis[N-(carboxymethyl)]-,chromium-51complex.
(Ethylenedinitrilo)tetraacetic acid,chromium-51complex
[27849-89-4].
Packaging and storage
Preserve in single-dose or multiple-dose containers,at a temperature between 2

and 8

.
Labeling
Label it to include the following,in addition to the information specified for
Labelingunder
Injections á1ñ:the time and date of calibration;the amount of
51Cr as edetate complex expressed as total MBq (or mCi)and as MBq (or mCi)per mLat the time of calibration;the expiration date;and the statement CautionRadioactive Material.The labeling indicates that in making dosage calculations,correction is to be made for radioactive decay and the quantity of chromium,and also indicates that the radioactive half-life of
51Cr is 27.8days.
Radionuclide identification (see Radioactivity á821ñ)
Its gamma-ray spectrum is identical to that of a specimen of
51Cr of known purity that exhibits a photopeak having an energy of 0.320MeV.
Bacterial endotoxins á85ñ:
not more than 175/
VUSP Endotoxin Unit per mLof the Injection,in which
Vis the maximum recommended total dose,in mL,at the expiration date or time.
Radiochemical purity
Electrolyte solution
Dissolve 0.2g of barbital sodium and 10g of sodium nitrate in water to make 1000mL.
Procedure
(see
Electrophoresis á726ñ)Soak a 2.5-cm ×17.0-cm ×0.22-mm cellulose strip in 100mLof
Electrolyte solutionfor 10to 60minutes.Remove the strip with forceps,and blot to remove excess solution.Attach the strip to the support bridge of an electrophoresis chamber containing
Electrolyte solution.Apply to the strip about 10µLof Injection as a 3-mm band at a position 10cm from the cathode.Attach the chamber cover,and perform the electrophoresis at 30Vper cm,using a stabilized current.Remove the strip from the chamber,and blot the ends.Using a suitable scanner and counting assembly,determine the radioactivity distribution:chromium
51Cr edetate moves about 5cm towards the anode;and
51Cr chromic ion moves about 7cm towards the cathode.The radioactivity of the chromium
51Cr edetate band is not less than 95%of the total radioactivity.
Radionuclidic purity
Using a suitable gamma-ray spectrometer (see
Selection of a Counting Assemblyin the
Assaysection under
Radioactivity á821ñ),determine the radioactivity of each radionuclidic impurity observed in the gamma-ray spectrum:not more than 0.1%of any individual impurity is found;and not more than 0.3%of total impurities is found.
Chemical purity
Using a validated limit test and a known analytical technique,demonstrate the absence of any ingredients and reagents employed in the synthetic process.
Limit of free chromium
Standard solution
Dissolve 0.96g of chromium potassium sulfate dodecahydrate and 2.87g of edetate disodium in 50mLof water,boil for 10minutes,cool,adjust with 0.2Msodium hydroxide to a pHbetween 3.5and 6.5,and dilute with water to 100.0mLto obtain a solution having a known concentration of about 1mg of chromium per mL.
Test solution
Use the Injection.
Procedure
Concomitantly determine the absorbances of the Standard solutionand the Test solutionat the wavelength of maximum absorbance at about 560nm,with a suitable spectrophotometer,using water as the blank:the absorbance of the Test solutionis not more than that of the Standard solution.
Other requirements
It meets the requirements under
Injections á1ñ,except that it is not subject to the recommendation on
Volume in Container.
Assay for radioactivity á821ñ
Using a suitable counting assembly (see
Selection of a Counting Assembly),determine the radioactivity,in MBq (or µCi)per mL,of Injection by use of a calibrated system.