1,2,3-Propanetricarboxylic acid,2-hydroxy-,gallium-67Ga(1:1)salt.
Gallium-67Gacitrate (1:1)
[41183-64-6;52260-70-5].
Packaging and storage
Preserve in single-dose or multiple-dose containers.
Labeling
Label it to include the following,in addition to the information specified for
Labelingunder
Injections á1ñ:the time and date of calibration;the amount of
67Ga as labeled gallium citrate expressed as total megabecquerels (MBq)(microcuries [µCi]or millicuries [mCi])and concentration as megabecquerels (µCi or mCi)per mLat the time of calibration;the expiration date and time;and the statement CautionRadioactive Material.The labeling indicates that in making dosage calibrations,correction is to be made for radioactive decay,and also indicates that the radioactive half-life of
67Ga is 78.26hours.
Bacterial endotoxins á85ñ
It meets the requirements of the
Bacterial Endotoxins Test,the limit of endotoxin content being not more than 175/
VUSP Endotoxin Unit per mLof the Injection,when compared with the USP Endotoxin RS,in which
Vis the maximum recommended total dose,in mL,at the expiration date or time.
Radiochemical purity
Place 10to 20µLof Injection about 3cm from one end of a 3-×55-cm strip of chromatographic paper (see
Chromatography á621ñ).While spots are wet,immediately develop the chromatogram at room temperature to the 14-cm mark by ascending chromatography,using a solvent system consisting of a mixture of 1.36g of sodium acetate and 0.58mLof glacial acetic acid in each 100mLof water.Allow the strip to partially dry,cover with clear tape,and determine the radioactivity distribution by scanning the chromatogram with a suitable collimated radiation detector:not less than 97.0%of the total radioactivity is found as gallium citrate when measured at the solvent front (
RFvalue equal to or greater than 0.9).
Radionuclidic purity
Using a suitable counting assembly (see
Selection of a Counting Assemblyunder
Radioactivity á821ñ),determine the radionuclidic purity of the Injection:not less than 99%of the total radioactivity is present as
67Ga at the time of calibration.
Other requirements
It meets the requirements under
Injections á1ñ,except that the Injection may be distributed or dispensed prior to the completion of the test for
Sterility,the latter test being started on the day of manufacture,and except that it is not subject to the recommendation on
Volume in Container.