Loss on drying á731ñ
Dry about 100mg,accurately weighed,of powdered Vaginal Tablets in a capillary-stoppered bottle in vacuum at a pressure not exceeding 5mm of mercury at 60

for 3hours:it loses not more than 3.0%of its weight.
Assay for oxytetracycline
Place not fewer than 5Vaginal Tablets in a high-speed blender jar containing an accurately measured volume of 0.1Nhydrochloric acid,so that the stock solution obtained after blending for 3to 5minutes contains not less than 150µg of oxytetracycline per mL.Proceed as directed for oxytetracycline under
AntibioticsMicrobial Assays á81ñ,using an accurately measured volume of this solution diluted quantitatively and stepwise with water to obtain a
Test Dilutionhaving a concentration of oxytetracycline assumed to be equal to the median dose level of the Standard.
Assay for polymyxin B
Weigh and finely powder not fewer than 5Vaginal Tablets.Transfer an accurately weighed portion of the powder,equivalent to about 100,000USP Polymyxin B Units,to a filter funnel equipped with a solvent-resistant membrane filter (1µm or finer porosity).Wash the powder with five 20-mLportions of acetone,applying vacuum,and discarding the accumulated filtrate.
[NOTEIf necessary,wash the powder with additional portions of acetone to remove any yellow color.
]Carefully transfer the filter and the washed powder to a beaker containing about 400mLof
Buffer No.6,and stir.Transfer the contents of the beaker to a 500-mLvolumetric flask with the aid of
Buffer No.6,dilute with the same solvent to volume,and mix.Proceed as directed for polymyxin Bunder
AntibioticsMicrobial Assays á81ñ,using an accurately measured volume of this solution diluted quantitatively and stepwise with
Buffer No.6to yield a
Test Dilutionhaving a concentration of polymyxin Bassumed to be equal to the median dose level of the Standard.