Identification
A:
Transfer 5mLto a separator containing 25mLof water,and extract the solution with two 25-mLportions of a mixture of equal volumes of ether and solvent hexane.Combine the extracts,and retain the water solution for
Identificationtest
B.Extract the ether-hexane solution with 50mLof water,and discard the water layer.Evaporate the ether-hexane solution to dryness,dry the residue in vacuum at 40

to 50

for 1hour,and dissolve the residue in 1mLof chloroform:the IRabsorption spectrum of this solution exhibits maxima at the same wavelengths as that of a similar solution of
USP Benzocaine RS,concomitantly measured.
B:
Add 5mLof 1Nsodium hydroxide solution to the water solution retained from
Identificationtest
A,and extract with two 25-mLportions of chloroform.Evaporate the combined extracts to dryness,dry the residue in vacuum at 40

to 50

for 1hour,and dissolve the residue in 3mLof chloroform:the IRabsorption spectrum of this solution exhibits maxima at the same wavelengths as that of a similar solution of
USP Antipyrine RS,concomitantly measured.
C:
The retention times of the major peaks in the chromatogram of the
Assay preparationcorrespond to those in the chromatogram of the
Standard preparation,as obtained in the
Assay.
Assay
Ammonium acetate solution
Dissolve 7.7g of ammonium acetate in water,dilute with water to 1000mL,and mix.
Mobile phase
Prepare a filtered and degassed mixture of
Ammonium acetate solutionand acetonitrile (3:1).Make adjustments if necessary (see
System Suitabilityunder
Chromatography á621ñ).
Standard preparation
Transfer about 15mg of
USP Benzocaine RS,accurately weighed,to a 100-mLvolumetric flask,add 15
Jmg of
USP Antipyrine RS,accurately weighed,
Jbeing the ratio of the labeled amount,in mg,of antipyrine to the labeled amount,in mg,of benzocaine per mLof Otic Solution.Add 50mLof methanol,dissolve in methanol,dilute with methanol to volume,and mix.Transfer 10.0mLof this solution to a 100-mLvolumetric flask,dilute with
Mobile phaseto volume,and mix.
Assay preparation
Transfer an accurately measured volume of Otic Solution,equivalent to about 15mg of benzocaine,to a 100-mLvolumetric flask.Dissolve in 50mLof methanol,dilute with methanol to volume,and mix.Transfer 10.0mLof this solution to a 100-mLvolumetric flask,dilute with Mobile phaseto volume,and mix.
Chromatographic system
(see
Chromatography á621ñ)The liquid chromatograph is equipped with a 280-nm detector and a 4-mm ×15-cm column that contains 5-µm packing L15.The flow rate is about 1.0mLper minute.Chromatograph the
Standard preparation,and record the peak responses as directed for
Procedure:the tailing factor for the benzocaine peak is not more than 2.5,the column efficiency for the benzocaine peaks is not less than 1500theoretical plates,and the relative standard deviation for replicate injections is not more than 2%.
Procedure
Separately inject equal volumes (about 10µL)of the
Standard preparationand the
Assay preparationinto the chromatograph,record the chromatograms,and measure the responses for the major peaks.The relative retention times are about 0.35for antipyrine,and 1.0for benzocaine.Calculate the quantity,in mg,of benzocaine (C
9H
11NO
2)in each mLof the Otic Solution taken by the formula:
1000(C/V)(rU/rS),
in which
Cis the concentration,in mg per mL,of
USP Benzocaine RSin the
Standard preparation;Vis the volume,in mL,of Otic Solution taken;and
rUand
rSare the peak responses due to benzocaine in the
Assay preparationand the
Standard preparation,respectively.Calculate the quantity,in mg,of antipyrine (C
11H
12N
2O)in each mLof the Otic Solution taken by the same formula,changing the terms to refer to antipyrine instead of benzocaine.